Take away the magnetic knob, press the on button, select the burner, slide the sliding control button, if the response is slow or no response, then you need to calibrate the magnetic knob, the calibration is as follows:
- Under the state of power off, press the child lock key to enter the child lock state, and the timer digital tube displays "Lo";
- Press the lower left burner selector key and the lower right burner selector key at the same time to enter the magnetic knob calibration mode, at this time the digital tube displays "cA";
- Immediately put the knob on and turn the magnetic knob clockwise 3 or more revolutions at normal speed, then counterclockwise 3 or more revolutions;
- Take down the magnetic knob and immediately press the off button to exit the magnetic knob calibration mode, long press the child lock button to release the child lock, the product returns to normal state.




Model: 10041381 (PI6041T-S5)
Take away all the magnetic knobs and press the on button, if the + and - key indicators do not light up, then the magnetic knobs need to be calibrated as follows:
- Under the state of power off, press the timer button and the lower left burner selector button at the same time and hold them for more than 3 seconds to enter the calibration mode of the magnetic knob of the upper left burner, and at this time, the digital tube of the upper left burner displays "cA";
- Immediately place the magnetic knob at the upper left burner selection key and turn the magnetic knob clockwise 3 or more turns at normal speed, then counterclockwise 3 or more turns;
- Press the Off button to exit the upper left burner magnetic knob calibration mode;
- Perform the magnetic knob calibration of the other three burners in sequence according to steps 1~3,
- press the Timer button and the upper left burner selector button at the same time and hold them for more than 3 seconds to enter the magnetic knob calibration mode of the upper left burner;
- press the Timer button and the upper right burner selector button at the same time and hold them for more than 3 seconds to enter the magnetic knob calibration mode of the lower right burner;
- press the Timer button and the lower right burner selector button at the same time and hold them for more than 3 seconds to enter the magnetic knob calibration mode of the upper right burner.